Guest Room Management

EURO ICC GUEST ROOM MANAGEMNET DEVICES IN UAE.

We offer EUROICC guest room management systems for hotels in UAE. EURO ICC is leading company in Europe for manufacturing and design guest room management devices in Serbia, PAKLINK LLC has stated hotel room management system installation and maintenance for EURO IIC devices in UAE, this Include controls room status such as do not disturb /make up room /guest occupancy. We also supply Automated HVAC control units, dimming control, lighting control, curtain/blind control and much more. The entire hotel room can be controlled via our Compact PLC Base devices with BACnet and Modbus communications.

RBFU 3.10 FIELD UNIT.Circuit

  • Digital I/O field unit
  • 12 digital inputs (potential free)
  • 230 V AC mains power
  • For DIN rail mounting

RBCPU 2.01 – RINGBUS MASTER

  • DIN rail mounting
  • For 1 fire ring or 1 smoke ring
  • Handles up to 500 field units or 1000 elements
  • 230 V AC mains power supply
  • Comprises of power supply, CPU and ring bus driver modules

RBCPU 2.10-LE – RINGBUS MASTER

  • 16 digital inputs
  • Counting capability on first two input
  • LED indication of the input circuit state
  • Optocoupled galvanic isolation 3.7 KV

We Supply and Install Guest Room devices in DUBAI UAE. 

  • smart thermostat for electric heater
  • Smart Glass touch panels
  • Program able room touch panel
  • Modular PLC with bacnet options
  • Compact series PLC with BACNET options
  • Guest Room Control Systems
  • Energy Management Systems
  • Lighting Controls
  • Integrated Room Solutions

BACNET PLC – M1.POW.01

  • Available ports: 1x Ethernet port, 4 x RS485 ports
  • Interchangeable ports for BACnet and Modbus
  • Device supports time synchronization
  • RTC (real-time clock) with backup power supply
  • LED indicators for device and communication status
  • Application layer relies on SQLite database, so that data collected from the networks are available even in case of communication loss.
  • Up to 32 of Bacnet/IP and Modbus/IP layers is supported through one Ethernet physical layer. Routing table is flexible and may contain 65533 entries.

BACNET PLC – M4.CPU.21

  • Possibility to store operating plans in non-volatile memory
  • Programming is done using PC application
  • Configuration, programming and debugging through USB port
  • RTC (real-time clock) with auxiliary power supply
  • Stand alone operation option
  • DIP switch selectable standard polarization and termination resistors on primary communication port
  • Modbus master expansion port with DIP switch selectable termination resistor and power supply output

BACNET PLC – M2.DIN.01

  • Possibility to store operating plans in non-volatile memory
  • Programming is done using PC application
  • Configuration, programming and debugging through USB port
  • RTC (real-time clock) with auxiliary power supply
  • Stand alone operation option
  • DIP switch selectable standard polarization and termination resistors on primary communication port
  • Modbus master expansion port with DIP switch selectable termination resistor and power supply output

BACNET PLC – M2.ANM.12

  • Possibility to store operating plans in non-volatile memory
  • Programming is done using PC application
  • Configuration, programming and debugging through USB port
  • RTC (real-time clock) with auxiliary power supply
  • Stand alone operation option
  • DIP switch selectable standard polarization and termination resistors on primary communication port
  • Modbus master expansion port with DIP switch selectable termination resistor and power supply output

BACNET PLC – M1.POW.01

  • Switch mode power supply
  • Built-in galvanic isolation
  • LED operation indicator
  • Built-in short circuit protection
  • Excessive current and temperature protection

BACNET PLC – M4.CPU.21

  • 10/100BASE-TX Ethernet port
  • USB device port, Type B
  • EBUS driver supports up to 16 U/I modules
  • Operating system: Linux 2.6.20.21 /uClibc with Xenomai RT patch

BACNET PLC – M2.DIN.01

  • Counting capability on first two input
  • 16 digital inputs
  • LED indication of the input circuit state
  • Optocoupled galvanic isolation 3.7 KV

BACNET PLC – M2.ANM.12

  • Inputs operate in self-scan mode
  • 8 analog inputs with maximum 16 bit resolution
  • Monotonicity with no missing codes is guarantied
  • Configuration of input type is performed by jumpers on the module
  • Excessive current and temperature protection